13 OMRON PLC 1
<E.g.> EM0:30000
Bank No.
Address No.
Colon
Available Memory
*
1When using EMn (extensional data memory), specify the bank
number (CV: 0 to 7, CS1: 0 to C).
The assigned memory is indicated while editing the screen as
illustrated:
Set the memory to the extent of the memory range of each PLC model.
Use TYPE number to assign indirect memory for macro programs.
CV
Memory TYPE Remarks
DM (data memory) 0
CH (input/output relay) 1
AR (alarm relay) 4
T (timer/current value) 5
C(counter/current value) 6
EMn (extensional data memory) 7 *1
TU (timer/contact) 9 Read only
CU (counter/contact) 10 Read only
CS1
Memory TYPE Remarks
DM (data memory) 0
CH (input/output relay) 1
H(holding relay) 2
A (alarm relay) 4
T (timer/current value) 5
C(counter/current value) 6
EMn (extensional data memory) 7
*
1
W (Internal Relay) 8
TU (timer/contact) 9 Read only
CU (counter/contact) 10 Read only
C
Memory TYPE Remarks
DM (data memory) 0
CH (input/output relay) 1
HR (holding relay) 2
LR (latch relay) 3
AR (alarm relay) 4
T (timer/current value) 5
C(counter/current value) 6
EMn (extensional data memory) 7 *1
TU (timer/contact) 9 Read only
CU (counter/contact) 10 Read only